Battery chargers
Phoenix 12/50 (2+1) 120-240V Victron Energy charger
Manufacturer: VICTRON ENERGY
INDEX: PCH012050001
Adaptive 4-stage charge characteristic: bulk - absorption - float - storage. Two full rated outputs and one 4 Amp output. Universal input 90-265V, 50/60Hz. The Phoenix charger features a microprocessor controlled adaptive battery management system that can be pre-set to suit different types of batteries. The adaptive feature will automatically optimise the charge process relative to the way the battery is being used.
Models: 12 / 24 Volts
Preventing damage due to excessive gassing: the BatterySafe mode (see fig. 2 below)
If, in order to quickly charge a battery, a high charge current in combination with a high absorption voltage has been chosen, the Phoenix Charger will prevent damage due to excessive gassing by automatically limiting the rate of voltage increase once the gassing voltage has been reached (see the charge curve between 14,4 V and 15,0 V in fig. 2 below).
Less maintenance and aging when the battery is not in use: the Storage mode (see fig. 1 & 2 below)
The storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the storage mode float voltage is reduced to 2,2 V/cell (13,2 V for 12 V battery) to minimize gassing and corrosion of the positive plates. Once a week the voltage is raised back to the absorption level to ‘equalize’ the battery. This feature prevents stratification of the electrolyte and sulphation, a major cause of early battery failure.
To increase battery life: temperature compensation
Every Phoenix Charger comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially.
Dimensions WxHxD [mm]: | 200 x 350 x 108 |
---|---|
Battery technology: | Klasyczny, AGM, Gel, Litowo-jonowy |
Communication type: | RS485 |
Weight [kg]: | 3.6 |
Dimensions [mm]: | 350.0 x 200.0 x 108.0 |
Battery capacity [Ah]: | 200 - 800 |
---|---|
Charge voltage, absorption [V]: | 14.4 |
Charge voltage, storage [V]: | 13.2 |
Input voltage range AC [V]: | 90 - 265 |
Input voltage range DC [V]: | 90 - 400 |
Nominal battery voltage [V]: | 12 |
Rated charge current [A]: | 50 |
Feed-in phases: | 1 |